Three-dimensional measurements of idiopathic macular holes using a scanning laser tomograph

Auteur(s) / Author(s)

WEINBERGER D. (1) ; STIEBEL H. (1) ; GATON D. D. (1) ; PRIEL E. ; YASSUR Y. (1) ;

Affiliation(s) du ou des auteurs / Author(s) Affiliation(s)

(1) Beilinson medical cent., dep. ophthalmology, Petah Tiqva 49 100, ISRAEL

Résumé / Abstract

Purpose : The diagnosis of macular holes is difficult. Confocal laser tomographic analysis of the retina permits the precise measurements of the macular surface. The authors used this technique to study the macular area of patients with full-thickness macular holes. The purposes of these studies is to perform three-dimensional measurements of the macular holes and their rims and to search for a correlation between these parameters. Methods : Thirty-one eyes with idiopathic full-thickness macular holes underwent scanning of their affected macular area using the Heidelberg retinal tomograph (HRT). The authors evaluated the following parameters : area of the hole and its elevated rim, the maximal depth of the hole, and the maximal elevation of the rim at 12, 3, 6, and 9 o'clock. Results : The average hole area was 0.33 mm2, and the rim area average was 2.99 mm2. The average area of the rim was found to be 9.06 times larger than that of the hole (P < 0.001). The depth of the hole averaged 144 μm. Conclusions : The area of the rim is usually bigger than that of the hole and in direct correlation to it. Also, the bigger the hole area, the greater its depth. The average height in each of the four quadrants (12, 3, 6, and 9 o'clock) correlates to the other quadrant heights (P < 0.001). Ophthalmology 1995 ;102 :1445-1449

Revue / Journal Title

Ophthalmology   ISSN 0161-6420   CODEN OPHTDG 

Source / Source

1995, vol. 102, no10, pp. 1445-1449 (16 ref.)

Langue / Language

Anglais

Editeur / Publisher

Elsevier, New York, NY, ETATS-UNIS  (1976) (Revue)

Mots-clés anglais / English Keywords

Macular hole ; Idiopathic ; Tridimensional tomography ; Scanning device ; Measurement method ; Human ; Eye disease ; Retinopathy ; Maculopathy ;

Mots-clés français / French Keywords

Trou maculaire ; Idiopathique ; Tomographie tridimensionnelle ; Dispositif balayage ; Méthode mesure ; Homme ; Oeil pathologie ; Rétinopathie ; Maculopathie ;

Mots-clés espagnols / Spanish Keywords

Agujero macular ; Idiopático ; Tomografía tridimensional ; Dispositivo barrido ; Método medida ; Hombre ; Ojo patología ; Retinopatía ; Maculopatía ;