CAT.INIST
Accueil du sitewww.cnrs.frwww.inist.frOther CNRS


COMMANDER / ORDER
PARTAGER / SHARE
EXPORT
Bookmark and Share
Mendeley    EndNote

Titre du document / Document title

Use of a physiologic oral glucose solution for screening for impaired glucose tolerance and non-insulin-dependent diabetes mellitus

Auteur(s) / Author(s)

PHILLIPS W. T. (1) ; TILSON K. S. (2) ; SCHWARTZ J. G. (2) ;

Affiliation(s) du ou des auteurs / Author(s) Affiliation(s)

(1) Department of Radiology, The University of Texas Health Science Center at San Antonio, ETATS-UNIS
(2) Department of Pathology,West Los Angeles, Calif, ETATS-UNIS

Résumé / Abstract

. Objective.-To evaluate a lower osmolar, more physiologic oral glucose solution as part of an oral glucose tolerance test and to compare it to the standard glucose solution to see if it could serve as an effective screening agent for patients with impaired glucose tolerance or non-insulin-dependent diabetes mellitus. Methods.-A total of 100 subjects were given both the standard (1.38 mol/L) 75-g oral glucose tolerance test solution and the lower osmolar (0.62 mol/L) 50-g glucose solution. Each test was separated by at least 3 days. Blood samples were drawn at baseline and 30, 60, and 120 minutes after ingestion of each glucose solution. The 1- and 2-hour blood glucose values obtained using the 75-g oral glucose tolerance test beverage were used as the gold standard to diagnose diabetes according to World Health Organization criteria. Results.-Both solutions were shown to have a high sensitivity and specificity for detecting diabetes and impaired glucose tolerance at 30 and 60 minutes. Conclusions.-The physiologic 50-g solution uses less glucose, is highly palatable, and is similar in sweetness and carbohydrate concentration to commonly consumed soda beverages. A larger study including more patients with impaired glucose tolerance will need to be performed to verify our conclusions. The ability to perform high-sensitivity and high-specificity screening for patients with diabetes or impaired glucose tolerance with a single timed blood sample could make mass screening more practical.

Revue / Journal Title

Archives of pathology & laboratory medicine   ISSN 0363-0153   CODEN APLMAS 

Source / Source

1996, vol. 120, no9, pp. 842-846 (42 ref.)

Langue / Language

Anglais

Editeur / Publisher

College of American Pathologists, Northbrook, IL, ETATS-UNIS  (1976) (Revue)

Mots-clés anglais / English Keywords

Non insulin dependent diabetes ; Glucose tolerance test ; Aqueous solution ; Glucose ; Osmolarity ; Comparative study ; Human ; Endocrinopathy ;

Mots-clés français / French Keywords

Diabète non insulinodépendant ; Hyperglycémie provoquée ; Solution aqueuse ; Glucose ; Osmolarité ; Etude comparative ; Homme ; Endocrinopathie ;

Mots-clés espagnols / Spanish Keywords

Diabetes no insulinodependiente ; Hiperglicemia provocada ; Solución acuosa ; Glucosa ; Osmolaridad ; Estudio comparativo ; Hombre ; Endocrinopatía ;

Localisation / Location

INIST-CNRS, Cote INIST : 2050, 35400006625314.0100

Nº notice refdoc (ud4) : 3233763

COMMANDER / ORDER
PARTAGER / SHARE
EXPORT
Bookmark and Share
Mendeley    EndNote

CAT.INIST