Disinfection of contact lenses without tap water rinsing : is it effective?

Auteur(s) / Author(s)

SEAL D. V. (1) ; DALTON A. (2) ; DORIS D. (3) ;

Affiliation(s) du ou des auteurs / Author(s) Affiliation(s)

(1) Tennent Institute of Ophthalmology, Western Infirmary, Glasgow G11 6NT, ROYAUME-UNI
(2) The Eye Clinic, Newcastle NE1 8JF, ROYAUME-UNI
(3) The Eye Clinic, Glasgow G2 1LU, ROYAUME-UNI

Résumé / Abstract

Purpose To establish the efficacy of the two most popular contact lens disinfecting systems - one-step hydrogen peroxide and multi-purpose disinfecting solution - for 1 month's use in practice in the absence of tap water rinsing. Methods This was a descriptive, prospective microbiological study of contact lens contamination with ideal hygiene compliance and new lenses and storage cases. One hundred and fifty contact lens wearers were instructed to avoid risk factors identified for Acanthamoeba infection. They were randomly assigned to use one of three disinfecting systems and taught to follow manufacturers' instructions. In addition, they were taught to avoid all use of tap water for contact lens hygiene, except for hand washing. Results There was no isolation of Acanthamoeba from any lens storage case, precluding the chance of amoebic infection. The multi-purpose solution gave the lowest rate of bacterial contamination, with 78% sterility and 15% of cases with < 104 bacteria/ml. For both one-step peroxide and multi-purpose solutions, Gram-negative bacteria were reduced in frequency compared with values expected historically, while Bacillus sp. were found more frequently. Storage cases of both one-step peroxide systems leaked fluid. Conclusions On the basis of contamination in previous studies, when hydrogen peroxide and other chemical disinfectants were used together with tap water washing, it was expected that approximately 40% of lens storage cases would yield bacteria, often with a high count, and that up to 8% would yield Acanthamoeba. Such contamination did not occur, however, in this study. The multi-purpose solution, for 1 month's use, gave the lowest rate of bacterial contamination with only 7% of storage cases harbouring bacteria at > 104/ml and with 78% sterility. One of the two one-step hydrogen peroxide systems performed equally well. Importantly, Acanthamoeba was not isolated from any of the 150 storage cases. Whether lens storage cases need to be sterile or contain < 103 bacteria/ml solution within them is debatable, but it is essential that Acanthamoeba be absent from them.

Revue / Journal Title

Eye   ISSN 0950-222X   CODEN EYEEEC 

Source / Source

1999, vol. 13 (2), pp. 226-230 (14 ref.)

Langue / Language

Anglais

Editeur / Publisher

Nature Publishing Group, Basingstoke, ROYAUME-UNI  (1987) (Revue)

Mots-clés anglais / English Keywords

Contact lens ; Solution ; Decontamination ; Hydrogen Peroxides ; Disinfecting agent ; Rinsing ; Efficiency ; Prospective ; Microbiological investigation ; Human ; Instrumentation therapy ;

Mots-clés français / French Keywords

Lentille cornéenne ; Solution ; Décontamination ; Hydrogène Peroxyde ; Désinfectant ; Rinçage ; Efficacité ; Prospective ; Exploration microbiologique ; Homme ; Traitement instrumental ;

Mots-clés espagnols / Spanish Keywords

Lente de contacto ; Solución ; Descontaminación ; Hidrógeno Peróxido ; Desinfectante ; Enjuague ; Eficacia ; Prospectiva ; Análisis microbiológico ; Hombre ; Tratamiento instrumental ;

Localisation / Location

INIST-CNRS, Cote INIST : 21076, 35400008431182.0180

Nº notice refdoc (ud4) : 1790948

COMMANDER / ORDER
PARTAGER / SHARE
EXPORT
Bookmark and Share
Mendeley    EndNote

CAT.INIST