CAT.INIST
Accueil du sitewww.cnrs.frwww.inist.frOther CNRS


COMMANDER / ORDER
PARTAGER / SHARE
EXPORT
Bookmark and Share
Mendeley    EndNote

Titre du document / Document title

A comparison between laser interferometric measurement of fundus pulsation and pneumotonometric measurement of pulsatile ocular blood flow. 1. Baseline considerations

Auteur(s) / Author(s)

SCHMETTERER L. (1 2) ; DALLINGER S. (1) ; FINDL O. (3) ; EICHLER H.-G. (1) ; WOLZT M. (1) ;

Affiliation(s) du ou des auteurs / Author(s) Affiliation(s)

(1) Department of Clinical Pharmacology, University of Vienna, Vienna, AUTRICHE
(2) Institute of Medical Physics, University of Vienna, Vienna, AUTRICHE
(3) Department of Ophthalmology, University of Vienna, Vienna, AUTRICHE

Résumé / Abstract

Purpose Several methods have been proposed for the investigation of the human choroidal circulation. The aim of the present study was to compare laser interferometric measurements of cardiac synchronous fundus pulsations with pneumotonometric measurements of intraocular pressure pulse and pulsatile ocular blood flow in humans. Methods The association between fundus pulsation amplitude as assessed with laser interferometry and pulse amplitude (PA) and pulsatile ocular blood flow (POBF) as assessed with pneumotonometry was investigated in 28 healthy subjects. Additionally, we investigated the distribution of fundus pulsation amplitude (FPA) in a region of -15° to +15° around the macula (n = 18) and the influence of accommodation paralysis with cyclopentolate on FPA (n = 10). Results There was a high association between FPA and PA (r = 0.86, p < 0.001) and FPA and POBF (r = 0.70, p < 0.001). Fundus pulsations in the macula were significantly smaller than in the optic disc, but significantly larger than those in peripheral regions of the retina. Administration of cyclopentolate did not influence FPA. Conclusions On the basis of the strong correlation between laser interferometric measurements of FPA and pneumotonometric measurements of PA and POBF, we conclude that the FPA is a valid index of pulsatile choroidal perfusion in humans.

Revue / Journal Title

Eye   ISSN 0950-222X   CODEN EYEEEC 

Source / Source

2000, vol. 14 (1), pp. 39-45 (43 ref.)

Langue / Language

Anglais

Editeur / Publisher

Nature Publishing Group, Basingstoke, ROYAUME-UNI  (1987) (Revue)

Mots-clés anglais / English Keywords

Blood flow ; Choroid ; Hemodynamics ; Measurement ; Measurement method ; Comparative study ; Laser interferometer ; Fundus of the eye ; Pneumotonometer ; Pulse ; Topography ; Eye ; Human ;

Mots-clés français / French Keywords

Débit sanguin ; Choroïde ; Hémodynamique ; Mesure ; Méthode mesure ; Etude comparative ; Interféromètre laser ; Fond oeil ; Tonomètre à air ; Pulsation ; Topographie ; Oeil ; Homme ;

Mots-clés espagnols / Spanish Keywords

Flujo sanguíneo ; Coroides ; Hemodinámica ; Medida ; Método medida ; Estudio comparativo ; Interferómetro laser ; Fondo ojo ; Neumotonómetro ; Pulsación ; Topografía ; Ojo ; Hombre ;

Localisation / Location

INIST-CNRS, Cote INIST : 21076, 35400008665045.0080

Nº notice refdoc (ud4) : 1400769

COMMANDER / ORDER
PARTAGER / SHARE
EXPORT
Bookmark and Share
Mendeley    EndNote

CAT.INIST